CVE-2024-7441 (GCVE-0-2024-7441)

Vulnerability from cvelistv5 – Published: 2024-08-03 17:31 – Updated: 2024-08-07 16:24 Unsupported When Assigned
VLAI
Title
Vivotek SD9364 httpd read stack-based overflow
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-07 16:17 UTC
CWE
  • CWE-121 - Stack-based Buffer Overflow
References
URL Tags
https://vuldb.com/?id.273526 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273526 signaturepermissions-required
https://vuldb.com/?submit.383842 third-party-advisory
https://yjz233.notion.site/vivotek-SD9364-has-sta… broken-linkexploit
Impacted products
Vendor Product Version
Vivotek SD9364 Affected: VVTK-0103f
Create a notification for this product.
vivotek sd9364_firmware Affected: vvtk-0103f
    cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sd9364_firmware",
            "vendor": "vivotek",
            "versions": [
              {
                "status": "affected",
                "version": "vvtk-0103f"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7441",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T16:17:09.130706Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-07T16:24:42.771Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "httpd"
          ],
          "product": "SD9364",
          "vendor": "Vivotek",
          "versions": [
            {
              "status": "affected",
              "version": "VVTK-0103f"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jylsec (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
        },
        {
          "lang": "de",
          "value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T17:31:04.573Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273526"
        },
        {
          "name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273526"
        },
        {
          "name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.383842"
        },
        {
          "tags": [
            "broken-link",
            "exploit"
          ],
          "url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:46:19.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Vivotek SD9364 httpd read stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7441",
    "datePublished": "2024-08-03T17:31:04.573Z",
    "dateReserved": "2024-08-02T21:36:37.042Z",
    "dateUpdated": "2024-08-07T16:24:42.771Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-7441",
      "date": "2026-10-03",
      "epss": "0.08131",
      "percentile": "0.94684"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:vivotek:sd9364_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sd9364_firmware",
                "vendor": "vivotek",
                "versions": [
                  {
                    "status": "affected",
                    "version": "vvtk-0103f"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7441",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-07T16:17:09.130706Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-07T16:24:34.234Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "httpd"
              ],
              "product": "SD9364",
              "vendor": "Vivotek",
              "versions": [
                {
                  "status": "affected",
                  "version": "VVTK-0103f"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "jylsec (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been declared as critical. This vulnerability affects the function read of the component httpd. The manipulation of the argument Content-Length leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-273526 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life."
            },
            {
              "lang": "de",
              "value": "In Vivotek SD9364 VVTK-0103f wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion read der Komponente httpd. Dank der Manipulation des Arguments Content-Length mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-03T17:31:04.573Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-273526 | Vivotek SD9364 httpd read stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.273526"
            },
            {
              "name": "VDB-273526 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.273526"
            },
            {
              "name": "Submit #383842 | vivotek SD9364 VVTK-0103f buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.383842"
            },
            {
              "tags": [
                "broken-link",
                "exploit"
              ],
              "url": "https://yjz233.notion.site/vivotek-SD9364-has-stack-buffer-overflow-vulnerability-in-httpd-c9dabd0511d04093865d1d75110429d1?pvs=4"
            }
          ],
          "tags": [
            "unsupported-when-assigned"
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-08-02T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-08-02T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-08-02T23:46:19.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Vivotek SD9364 httpd read stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-7441",
        "datePublished": "2024-08-03T17:31:04.573Z",
        "dateReserved": "2024-08-02T21:36:37.042Z",
        "dateUpdated": "2024-08-07T16:24:42.771Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…