CVE-2023-52891 (GCVE-0-2023-52891)

Vulnerability from cvelistv5 – Published: 2024-07-09 12:04 – Updated: 2025-08-27 20:42
VLAI
Summary
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-09 13:26 UTC
CWE
  • CWE-1325 - Improperly Controlled Sequential Memory Allocation
Impacted products
Vendor Product Version
Siemens SIMATIC Energy Manager Basic Affected: 0 , < V7.5 (custom)
Create a notification for this product.
Siemens SIMATIC Energy Manager PRO Affected: 0 , < V7.5 (custom)
Create a notification for this product.
Siemens SIMATIC IPC DiagBase Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMATIC IPC DiagMonitor Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMIT V10 Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMIT V11 Affected: 0 , < V11.1 (custom)
Create a notification for this product.
siemens simatic_energy_manager_basic Affected: 0 , < V7.5 (custom)
    cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*
Create a notification for this product.
siemens simatic_energy_manager_pro Affected: 0 , < V7.5 (custom)
    cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*
Create a notification for this product.
siemens simatic_ipc_diagbase Affected: 0 , ≤ * (custom)
    cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens simatic_ipc_diagmonitor Affected: 0 , ≤ * (custom)
    cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*
Create a notification for this product.
siemens simit_v10 Affected: 0 , ≤ * (custom)
    cpe:2.3:a:siemens:simit_v10:*:*:*:*:*:*:*:*
Create a notification for this product.
siemens simit_v11 Affected: 0 , < V11.1 (custom)
    cpe:2.3:a:siemens:simit_v11:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_energy_manager_basic",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V7.5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_energy_manager_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V7.5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_ipc_diagbase",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_ipc_diagmonitor",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:simit_v10:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simit_v10",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:simit_v11:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simit_v11",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "V11.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-52891",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T13:26:14.481281Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T20:42:53.094Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:18:41.378Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Manager Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Manager PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC DiagBase",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMIT V10",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMIT V11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V11.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.5), SIMATIC Energy Manager PRO (All versions \u003c V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions \u003c V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1325",
              "description": "CWE-1325: Improperly Controlled Sequential Memory Allocation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:04:42.619Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-52891",
    "datePublished": "2024-07-09T12:04:42.619Z",
    "dateReserved": "2024-06-21T15:06:40.772Z",
    "dateUpdated": "2025-08-27T20:42:53.094Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-52891",
      "date": "2026-10-03",
      "epss": "0.00465",
      "percentile": "0.38075"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:18:41.378Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_energy_manager_basic",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V7.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_energy_manager_pro",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V7.5",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_ipc_diagbase:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_ipc_diagbase",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simatic_ipc_diagmonitor",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simit_v10:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simit_v10",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThanOrEqual": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:siemens:simit_v11:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "simit_v11",
                "vendor": "siemens",
                "versions": [
                  {
                    "lessThan": "V11.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-52891",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-09T13:26:14.481281Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-09T13:28:22.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Energy Manager Basic",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Energy Manager PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC DiagBase",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC DiagMonitor",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMIT V10",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMIT V11",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V11.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.5), SIMATIC Energy Manager PRO (All versions \u003c V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions \u003c V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1325",
                  "description": "CWE-1325: Improperly Controlled Sequential Memory Allocation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-09T12:04:42.619Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-088132.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-52891",
        "datePublished": "2024-07-09T12:04:42.619Z",
        "dateReserved": "2024-06-21T15:06:40.772Z",
        "dateUpdated": "2025-08-27T20:42:53.094Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…