A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-02 13:48 UTC
CWE
  • Insecure GUI
  • CWE-317 - Cleartext Storage of Sensitive Information in GUI
References
Impacted products
Vendor Product Version
Lenovo System Update Affected: various
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:25:40.291Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.infosec.tirol/cve-2022-0354/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-0354",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-02T13:48:54.060069Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-317",
                "description": "CWE-317 Cleartext Storage of Sensitive Information in GUI",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-02T13:50:02.923Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "System Update",
          "vendor": "Lenovo",
          "versions": [
            {
              "status": "affected",
              "version": "various"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Insecure GUI",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-26T22:24:43.000Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.infosec.tirol/cve-2022-0354/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Follow Mitigation Strategy in LEN-76673."
        }
      ],
      "source": {
        "advisory": "LEN-76673",
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "ID": "CVE-2022-0354",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "System Update",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "various"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Insecure GUI"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/product_security/LEN-76673",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
            },
            {
              "name": "https://www.infosec.tirol/cve-2022-0354/",
              "refsource": "MISC",
              "url": "https://www.infosec.tirol/cve-2022-0354/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Follow Mitigation Strategy in LEN-76673."
          }
        ],
        "source": {
          "advisory": "LEN-76673",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2022-0354",
    "datePublished": "2022-04-22T20:30:47.000Z",
    "dateReserved": "2022-01-24T00:00:00.000Z",
    "dateUpdated": "2026-06-02T13:50:02.923Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-0354",
      "date": "2026-10-03",
      "epss": "0.00256",
      "percentile": "0.156"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T23:25:40.291Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.infosec.tirol/cve-2022-0354/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-0354",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T13:48:54.060069Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-317",
                    "description": "CWE-317 Cleartext Storage of Sensitive Information in GUI",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T13:49:58.840Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "System Update",
              "vendor": "Lenovo",
              "versions": [
                {
                  "status": "affected",
                  "version": "various"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Insecure GUI",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-26T22:24:43.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.infosec.tirol/cve-2022-0354/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Follow Mitigation Strategy in LEN-76673."
            }
          ],
          "source": {
            "advisory": "LEN-76673",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "ID": "CVE-2022-0354",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "System Update",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "various"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Daniel Feichter (@VirtualAllocEx) at Infosec Tirol for reporting this issue."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Insecure GUI"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-76673",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-76673"
                },
                {
                  "name": "https://www.infosec.tirol/cve-2022-0354/",
                  "refsource": "MISC",
                  "url": "https://www.infosec.tirol/cve-2022-0354/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Follow Mitigation Strategy in LEN-76673."
              }
            ],
            "source": {
              "advisory": "LEN-76673",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2022-0354",
        "datePublished": "2022-04-22T20:30:47.000Z",
        "dateReserved": "2022-01-24T00:00:00.000Z",
        "dateUpdated": "2026-06-02T13:50:02.923Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…