Search
Find a vulnerability
Search criteria
1 vulnerability by Norwegian Cruise Line
CVE-2026-75907 (GCVE-0-2026-75907)
Vulnerability from cvelistv5 โ Published: 2026-09-24 15:56 โ Updated: 2026-09-24 18:01
VLAI
EPSS
VEX
Title
CVE-2026-75907
Summary
The door access control on a Norwegian Cruise Line asset grants entry based only on the credential's static 7-byte UID stored on an NTAG212 NFC chip. A UID is a manufacturer serial number sent in the clear on every read and is not intended to be secret or to authenticate the holder. Validating on the UID of the NTAG212 NFC chip alone is identification, not authentication, and the credential has no challenge-response capability that would resist copying.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-09-24 18:01 UTC
CWE
- CWE-287 Improper Authentication
- CWE-294 Authentication Bypass by Capture-replay
- CWE-613 Insufficient Session Expiration
- CWE-287 - Improper Authentication
- CWE-294 - Authentication Bypass by Capture-replay
- CWE-613 - Insufficient Session Expiration
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Norwegian Cruise Line | door access control |
Affected:
N/A
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-09-24T17:07:43.376Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.kb.cert.org/vuls/id/676317"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2026-75907",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-24T18:01:05.357661Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
},
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
},
{
"cweId": "CWE-613",
"description": "CWE-613 Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T18:01:38.228Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "door access control",
"vendor": "Norwegian Cruise Line",
"versions": [
{
"status": "affected",
"version": "N/A"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The door access control on a Norwegian Cruise Line asset grants entry based only on the credential\u0027s static 7-byte UID stored on an NTAG212 NFC chip. A UID is a manufacturer serial number sent in the clear on every read and is not intended to be secret or to authenticate the holder. Validating on the UID of the NTAG212 NFC chip alone is identification, not authentication, and the credential has no challenge-response capability that would resist copying."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-287 Improper Authentication",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en"
}
]
},
{
"descriptions": [
{
"description": "CWE-613 Insufficient Session Expiration",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T15:56:08.200Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://kb.cert.org/vuls/id/676317"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CVE-2026-75907",
"x_generator": {
"engine": "VINCE 3.0.49",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2026-75907"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2026-75907",
"datePublished": "2026-09-24T15:56:08.200Z",
"dateReserved": "2026-08-18T14:59:09.975Z",
"dateUpdated": "2026-09-24T18:01:38.228Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}