Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for struxureware_data_center_expert by schneider-electric

    CVE-2023-37199 (GCVE-0-2023-37199)

    Vulnerability from cvelistv5 – Published: 2023-07-12 07:04 – Updated: 2024-11-07 14:44
    VLAI
    Summary
    A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE tampers with backups which are then manually restored.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-07 14:42 UTC
    CWE
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Impacted products
    Vendor Product Version
    Schneider Electric StruxureWare Data Center Expert Affected: v7.9.3 and earlier
    Create a notification for this product.
    schneider-electric struxureware_data_center_expert Affected: 0 , ≤ 7.9.3 (custom)
        cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:33.130Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "struxureware_data_center_expert",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "7.9.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37199",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-07T14:42:11.667073Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-07T14:44:46.940Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StruxureWare Data Center Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v7.9.3 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE tampers with backups which\nare then manually restored. \n\n\n"
                }
              ],
              "value": "\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE tampers with backups which\nare then manually restored. \n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-94",
                  "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-12T07:04:08.510Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-37199",
        "datePublished": "2023-07-12T07:04:08.510Z",
        "dateReserved": "2023-06-28T14:14:13.863Z",
        "dateUpdated": "2024-11-07T14:44:46.940Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-37198 (GCVE-0-2023-37198)

    Vulnerability from cvelistv5 – Published: 2023-07-12 06:44 – Updated: 2024-11-07 14:45
    VLAI
    Summary
    A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-07 14:42 UTC
    CWE
    • CWE-94 - Improper Control of Generation of Code ('Code Injection')
    Impacted products
    Vendor Product Version
    Schneider Electric StruxureWare Data Center Expert Affected: v7.9.3 and earlier
    Create a notification for this product.
    schneider-electric struxureware_data_center_expert Affected: 0 , ≤ 7.9.3 (custom)
        cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-07-11 06:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:33.057Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "struxureware_data_center_expert",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "7.9.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37198",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-07T14:42:18.221049Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-07T14:45:30.711Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StruxureWare Data Center Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v7.9.3 and earlier"
                }
              ]
            }
          ],
          "datePublic": "2023-07-11T06:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE uploads or tampers with install\npackages. \n\n \n\n\n\n"
                }
              ],
              "value": "\n\n\n\n\nA CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that\ncould cause remote code execution when an admin user on DCE uploads or tampers with install\npackages. \n\n \n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-94",
                  "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-12T06:44:34.037Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-37198",
        "datePublished": "2023-07-12T06:44:34.037Z",
        "dateReserved": "2023-06-28T14:14:13.863Z",
        "dateUpdated": "2024-11-07T14:45:30.711Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-37197 (GCVE-0-2023-37197)

    Vulnerability from cvelistv5 – Published: 2023-07-12 06:41 – Updated: 2024-11-07 14:46
    VLAI
    Summary
    A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-07 14:42 UTC
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Impacted products
    Vendor Product Version
    Schneider Electric StruxureWare Data Center Expert Affected: v7.9.3 and earlier
    Create a notification for this product.
    schneider-electric struxureware_data_center_expert Affected: 0 , ≤ 7.9.3 (custom)
        cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-07-11 06:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:33.407Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "struxureware_data_center_expert",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "7.9.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37197",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-07T14:42:24.492097Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-07T14:46:11.017Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StruxureWare Data Center Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v7.9.3 and earlier"
                }
              ]
            }
          ],
          "datePublic": "2023-07-11T06:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the mass configuration settings of endpoints on DCE. \n\n\n\n"
                }
              ],
              "value": "\n\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the mass configuration settings of endpoints on DCE. \n\n\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-12T06:41:30.783Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-37197",
        "datePublished": "2023-07-12T06:41:30.783Z",
        "dateReserved": "2023-06-28T14:14:13.863Z",
        "dateUpdated": "2024-11-07T14:46:11.017Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-37196 (GCVE-0-2023-37196)

    Vulnerability from cvelistv5 – Published: 2023-07-12 06:22 – Updated: 2024-11-07 14:46
    VLAI
    Summary
    A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-11-07 14:42 UTC
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Impacted products
    Vendor Product Version
    Schneider Electric StruxureWare Data Center Expert Affected: v7.9.3 and earlier
    Create a notification for this product.
    schneider-electric struxureware_data_center_expert Affected: 0 , ≤ 7.9.3 (custom)
        cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-07-11 06:22
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:32.952Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schneider-electric:struxureware_data_center_expert:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "struxureware_data_center_expert",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "7.9.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37196",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-07T14:42:31.489133Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-07T14:46:44.245Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StruxureWare Data Center Expert ",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "v7.9.3 and earlier"
                }
              ]
            }
          ],
          "datePublic": "2023-07-11T06:22:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the alert settings of endpoints on DCE.\n\n"
                }
              ],
              "value": "\nA CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command\n(\u0027SQL Injection\u0027) vulnerability exists that could allow a user already authenticated on DCE to\naccess unauthorized content, change, or delete content, or perform unauthorized actions when\ntampering with the alert settings of endpoints on DCE.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-07-12T06:22:46.848Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-192-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2023-37196",
        "datePublished": "2023-07-12T06:22:46.848Z",
        "dateReserved": "2023-06-28T14:14:13.863Z",
        "dateUpdated": "2024-11-07T14:46:44.245Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }