CVE-2024-33698 (GCVE-0-2024-33698)
Vulnerability from cvelistv5 – Published: 2024-09-10 09:36 – Updated: 2025-10-14 09:15
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 17:32 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Opcenter Quality |
Affected:
0 , < V2406
(custom)
|
|
| Siemens | Opcenter RDnL |
Affected:
0 , < V2410
(custom)
|
|
| Siemens | SIMATIC PCS neo V4.0 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC PCS neo V4.1 |
Affected:
0 , < V4.1 Update 2
(custom)
|
|
| Siemens | SIMATIC PCS neo V5.0 |
Affected:
0 , < V5.0 Update 1
(custom)
|
|
| Siemens | SINEC NMS |
Affected:
0 , < *
(custom)
|
|
| Siemens | SINEMA Remote Connect Client |
Affected:
0 , < V3.2 SP3
(custom)
|
|
| Siemens | Totally Integrated Automation Portal (TIA Portal) V16 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Totally Integrated Automation Portal (TIA Portal) V17 |
Affected:
0 , < V17 Update 8
(custom)
|
|
| Siemens | Totally Integrated Automation Portal (TIA Portal) V18 |
Affected:
0 , < V18 Update 5
(custom)
|
|
| Siemens | Totally Integrated Automation Portal (TIA Portal) V19 |
Affected:
0 , < V19 Update 3
(custom)
|
|
| siemens | simatic_pcs_neo |
Affected:
4.0 , < 4.1_update_2
(custom)
cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:* |
|
| siemens | simatic_information_server |
Affected:
0 , < *
(custom)
cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:* cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:* cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:* cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:* cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:* |
|
| siemens | totally_integrated_automation_portal |
Affected:
17 , < 17_update_8
(custom)
cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_pcs_neo",
"vendor": "siemens",
"versions": [
{
"lessThan": "4.1_update_2",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_information_server:2022:*:*:*:*:*:*:*",
"cpe:2.3:a:siemens:simatic_information_server:2024:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_information_server",
"vendor": "siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "totally_integrated_automation_portal",
"vendor": "siemens",
"versions": [
{
"lessThan": "17_update_8",
"status": "affected",
"version": "17",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33698",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T17:32:07.999463Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T18:26:36.889Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2410",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V4.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V4.1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1 Update 2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PCS neo V5.0",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.0 Update 1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINEMA Remote Connect Client",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.2 SP3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V17 Update 8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V18 Update 5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Totally Integrated Automation Portal (TIA Portal) V19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V19 Update 3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2406), Opcenter RDnL (All versions \u003c V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions \u003c V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions \u003c V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions \u003c V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:00.448Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-039007.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-33698",
"datePublished": "2024-09-10T09:36:31.009Z",
"dateReserved": "2024-04-26T12:32:09.263Z",
"dateUpdated": "2025-10-14T09:15:00.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}