Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for CodeMeter by Wibu

    CVE-2020-37017 (GCVE-0-2020-37017)

    Vulnerability from cvelistv5 – Published: 2026-01-29 14:28 – Updated: 2026-03-05 01:27 Disputed
    VLAI
    Title
    CodeMeter 6.60 - 'CodeMeter.exe' Unquoted Service Path
    Summary
    CodeMeter 6.60 contains an unquoted service path vulnerability that allows local users to potentially execute arbitrary code with elevated system privileges. Attackers can exploit the unquoted binary path in the CodeMeter Runtime Server service to inject malicious code that would execute with LocalSystem permissions.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-29 15:06 UTC
    CWE
    • CWE-428 - Unquoted Search Path or Element
    Impacted products
    Vendor Product Version
    Wibu CodeMeter Affected: 6.60
        cpe:2.3:a:wibu:codemeter:6.60:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2020-08-05 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-37017",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-29T15:06:31.083844Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-29T15:07:09.684Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CodeMeter",
              "vendor": "Wibu",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.60"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:wibu:codemeter:6.60:*:*:*:*:*:*:*",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Luis Martinez"
            }
          ],
          "datePublic": "2020-08-05T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eCodeMeter 6.60 contains an unquoted service path vulnerability that allows local users to potentially execute arbitrary code with elevated system privileges. Attackers can exploit the unquoted binary path in the CodeMeter Runtime Server service to inject malicious code that would execute with LocalSystem permissions.\u003c/p\u003e"
                }
              ],
              "value": "CodeMeter 6.60 contains an unquoted service path vulnerability that allows local users to potentially execute arbitrary code with elevated system privileges. Attackers can exploit the unquoted binary path in the CodeMeter Runtime Server service to inject malicious code that would execute with LocalSystem permissions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-428",
                  "description": "Unquoted Search Path or Element",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-05T01:27:27.506Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "name": "ExploitDB-48735",
              "tags": [
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/48735"
            },
            {
              "name": "CodeMeter Runtime Product Homepage",
              "tags": [
                "product"
              ],
              "url": "https://www.wibu.com/us/products/codemeter/runtime.html"
            },
            {
              "name": "VulnCheck Advisory: CodeMeter 6.60 - \u0027CodeMeter.exe\u0027 Unquoted Service Path",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/codemeter-codemeterexe-unquoted-service-path"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "disputed"
          ],
          "title": "CodeMeter 6.60 - \u0027CodeMeter.exe\u0027 Unquoted Service Path",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2020-37017",
        "datePublished": "2026-01-29T14:28:33.069Z",
        "dateReserved": "2026-01-28T18:18:30.521Z",
        "dateUpdated": "2026-03-05T01:27:27.506Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-47809 (GCVE-0-2025-47809)

    Vulnerability from cvelistv5 – Published: 2025-05-16 00:00 – Updated: 2026-09-08 08:42
    VLAI
    Summary
    Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-05-16 13:35 UTC
    CWE
    • CWE-272 - Least Privilege Violation
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-47809",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-16T13:35:54.604112Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-16T13:36:00.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V5.0",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V5.1",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.0 QU2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V7",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.0 QU2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC PDM Maintenance Station V5.0",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.0 SP2",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.18",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.18 P032",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.19",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.19 P020",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20 P008",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-08T08:42:59.701Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-331739.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-201595.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CodeMeter",
              "vendor": "Wibu",
              "versions": [
                {
                  "lessThan": "8.30a",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "8.30a",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-272",
                  "description": "CWE-272 Least Privilege Violation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-05-16T00:18:40.444Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.wibu.com/support/security-advisories/wibu-100120.html"
            }
          ],
          "x_generator": {
            "engine": "enrichogram 0.0.1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-47809",
        "datePublished": "2025-05-16T00:00:00.000Z",
        "dateReserved": "2025-05-10T00:00:00.000Z",
        "dateUpdated": "2026-09-08T08:42:59.701Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }