Common Weakness Enumeration
CWE-598
AllowedUse of HTTP Request With Sensitive Query String
Abstraction: Variant · Status: Draft
The web application uses an HTTP method to process a request, but the request includes sensitive information in the query string.
165 vulnerabilities reference this CWE, most recent first.
CVE-2026-2237 (GCVE-0-2026-2237)
Vulnerability from cvelistv5 – Published: 2026-05-27 08:44 – Updated: 2026-06-02 08:28
VLAI
EPSS
VEX
Summary
A use of get request method with sensitive query strings vulnerability in volume encryption of Synology Storage Manager package before 1.0.1-1100 allows local users on Windows to obtain sensitive information.
Severity
6.2 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-27 12:12 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.synology.com/en-global/security/advis… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Synology | Storage Manager |
Affected:
* , < 1.0.1-1100
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2237",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T12:12:11.329662Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T12:12:26.271Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Storage Manager",
"vendor": "Synology",
"versions": [
{
"lessThan": "1.0.1-1100",
"status": "affected",
"version": "*",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Simon Baaske (Serviceware)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A use of get request method with sensitive query strings vulnerability in volume encryption of Synology Storage Manager package before 1.0.1-1100 allows local users on Windows to obtain sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T08:28:36.196Z",
"orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"shortName": "synology"
},
"references": [
{
"name": "Synology-SA-26:01 Storage Manager",
"tags": [
"vendor-advisory"
],
"url": "https://www.synology.com/en-global/security/advisory/Synology_SA_26_01"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"assignerShortName": "synology",
"cveId": "CVE-2026-2237",
"datePublished": "2026-05-27T08:44:29.472Z",
"dateReserved": "2026-02-09T06:21:48.344Z",
"dateUpdated": "2026-06-02T08:28:36.196Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-69270 (GCVE-0-2025-69270)
Vulnerability from cvelistv5 – Published: 2026-01-12 04:20 – Updated: 2026-01-12 15:21
VLAI
EPSS
VEX
Title
Spectrum session token in URL
Summary
Information Exposure Through Query Strings in GET Request vulnerability in Broadcom DX NetOps Spectrum on Windows, Linux allows Session Hijacking.This issue affects DX NetOps Spectrum: 24.3.8 and earlier.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-12 15:21 UTC
CWE
- CWE-598 - Information Exposure Through Query Strings in GET Request
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://support.broadcom.com/web/ecx/support-cont… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Broadcom | DX NetOps Spectrum |
Affected:
24.3.8 and earlier
(custom)
Unaffected: 24.3.9 and later (custom) cpe:2.3:a:broadcom:dx_netops_spectrum:24.3.8_and_earlier:*:windows:*:*:*:*:* cpe:2.3:a:broadcom:dx_netops_spectrum:24.3.8_and_earlier:*:linux:*:*:*:*:* |
Date Public
2026-01-12 04:15
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-69270",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-12T15:21:01.996598Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-12T15:21:09.808Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"Linux"
],
"product": "DX NetOps Spectrum",
"vendor": "Broadcom",
"versions": [
{
"status": "affected",
"version": "24.3.8 and earlier",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "24.3.9 and later",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:broadcom:dx_netops_spectrum:24.3.8_and_earlier:*:windows:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:broadcom:dx_netops_spectrum:24.3.8_and_earlier:*:linux:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:broadcom:dx_netops_spectrum:24.3.9_and_later:*:windows:*:*:*:*:*",
"vulnerable": false
},
{
"criteria": "cpe:2.3:a:broadcom:dx_netops_spectrum:24.3.9_and_later:*:linux:*:*:*:*:*",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jean-Michel Huguet and Jorge Escabias from NATO Cyber Security Centre"
}
],
"datePublic": "2026-01-12T04:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Information Exposure Through Query Strings in GET Request vulnerability in Broadcom DX NetOps Spectrum on Windows, Linux allows Session Hijacking.\u003cp\u003eThis issue affects DX NetOps Spectrum: 24.3.8 and earlier.\u003c/p\u003e"
}
],
"value": "Information Exposure Through Query Strings in GET Request vulnerability in Broadcom DX NetOps Spectrum on Windows, Linux allows Session Hijacking.This issue affects DX NetOps Spectrum: 24.3.8 and earlier."
}
],
"impacts": [
{
"capecId": "CAPEC-593",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-593 Session Hijacking"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 2.3,
"baseSeverity": "LOW",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Information Exposure Through Query Strings in GET Request",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-12T04:35:06.225Z",
"orgId": "e291eae9-7c0a-46ac-ba7d-5251811f8b7f",
"shortName": "ca"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://support.broadcom.com/web/ecx/support-content-notification/-/external/content/SecurityAdvisories/0/36756"
}
],
"source": {
"advisory": "CA20260112-01: Security Notice for DX NetOps Spectrum",
"discovery": "EXTERNAL"
},
"title": "Spectrum session token in URL",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e291eae9-7c0a-46ac-ba7d-5251811f8b7f",
"assignerShortName": "ca",
"cveId": "CVE-2025-69270",
"datePublished": "2026-01-12T04:20:13.446Z",
"dateReserved": "2025-12-31T03:22:49.490Z",
"dateUpdated": "2026-01-12T15:21:09.808Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-62317 (GCVE-0-2025-62317)
Vulnerability from cvelistv5 – Published: 2026-05-14 16:13 – Updated: 2026-05-14 18:31
VLAI
EPSS
VEX
Title
HCL AION is affected by a vulnerability where sensitive information may be included in URL parameters.
Summary
HCL AION is affected by a vulnerability where sensitive information may be included in URL parameters. Passing sensitive data in URLs may expose it through browser history, logs, or intermediary systems, potentially leading to unintended information disclosure under certain conditions.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-14 18:31 UTC
CWE
- CWE-598 - Use of HTTP Request With Sensitive Query String
Assigner
References
1 reference
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-62317",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-14T18:31:31.916059Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-14T18:31:43.789Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AION",
"vendor": "HCL",
"versions": [
{
"status": "affected",
"version": "2.1.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "HCL AION is affected by a vulnerability where sensitive information may be included in URL parameters. Passing sensitive data in URLs may expose it through browser history, logs, or intermediary systems, potentially leading to unintended information disclosure under certain conditions."
}
],
"value": "HCL AION is affected by a vulnerability where sensitive information may be included in URL parameters. Passing sensitive data in URLs may expose it through browser history, logs, or intermediary systems, potentially leading to unintended information disclosure under certain conditions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.6,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:R/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598: Use of HTTP Request With Sensitive Query String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-14T16:13:34.907Z",
"orgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"shortName": "HCL"
},
"references": [
{
"url": "https://support.hcl-software.com/csm?id=kb_article\u0026sysparm_article=KB0130636"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "HCL AION is affected by a vulnerability where sensitive information may be included in URL parameters.",
"x_generator": {
"engine": "Vulnogram 1.0.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "1e47fe04-f25f-42fa-b674-36de2c5e3cfc",
"assignerShortName": "HCL",
"cveId": "CVE-2025-62317",
"datePublished": "2026-05-14T16:13:34.907Z",
"dateReserved": "2025-10-10T09:04:16.878Z",
"dateUpdated": "2026-05-14T18:31:43.789Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-58584 (GCVE-0-2025-58584)
Vulnerability from cvelistv5 – Published: 2025-10-06 07:01 – Updated: 2026-05-13 11:55
VLAI
EPSS
VEX
Title
Plain Text Transmission of Username and Password in the URL
Summary
In the HTTP request, the username and password are transferred directly in the URL as parameters. However, URLs can be stored in various systems such as server logs, browser histories or proxy servers. As a result, there is a high risk that this sensitive data will be disclosed unintentionally.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-06 16:37 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://sick.com/psirt | x_SICK PSIRT Security Advisories |
| https://www.sick.com/media/docs/9/19/719/special_… | x_SICK Operating Guidelines |
| https://www.cisa.gov/resources-tools/resources/ic… | x_ICS-CERT recommended practices on Industrial Security |
| https://www.first.org/cvss/calculator/3.1 | x_CVSS v3.1 Calculator |
| https://www.sick.com/.well-known/csaf/white/2025/… | x_The canonical URL. |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisory |
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| SICK AG | Baggage Analytics |
Affected:
0 , < 4.6.3
(custom)
|
|
| SICK AG | Tire Analytics |
Affected:
0 , < 4.6.3
(custom)
|
|
| SICK AG | Package Analytics |
Affected:
0 , < 4.6.3
(custom)
|
|
| SICK AG | Logistic Diagnostic Analytics |
Affected:
0 , < 4.6.3
(custom)
|
|
| SICK AG | Enterprise Analytics |
Affected:
all versions
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-58584",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-06T16:37:16.225888Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T16:37:23.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "Baggage Analytics",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "4.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Tire Analytics",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "4.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Package Analytics",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "4.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Logistic Diagnostic Analytics",
"vendor": "SICK AG",
"versions": [
{
"lessThan": "4.6.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "Enterprise Analytics",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn the HTTP request, the username and password are transferred directly in the URL as parameters. However, URLs can be stored in various systems such as server logs, browser histories or proxy servers. As a result, there is a high risk that this sensitive data will be disclosed unintentionally.\u003c/p\u003e"
}
],
"value": "In the HTTP request, the username and password are transferred directly in the URL as parameters. However, URLs can be stored in various systems such as server logs, browser histories or proxy servers. As a result, there is a high risk that this sensitive data will be disclosed unintentionally."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T11:55:11.969Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"x_SICK PSIRT Security Advisories"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"x_SICK Operating Guidelines"
],
"url": "https://www.sick.com/media/docs/9/19/719/special_information_sick_operating_guidelines_cybersecurity_by_sick_en_im0106719.pdf"
},
{
"tags": [
"x_ICS-CERT recommended practices on Industrial Security"
],
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"tags": [
"x_CVSS v3.1 Calculator"
],
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"tags": [
"x_The canonical URL."
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.json"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0010.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For Logistic Analytics Products: It is strongly recommended to update the product to version 4.6.3.\u0026nbsp;\u003cbr\u003e"
}
],
"value": "For Logistic Analytics Products: It is strongly recommended to update the product to version 4.6.3."
}
],
"source": {
"advisory": "SCA-2025-0010",
"discovery": "INTERNAL"
},
"title": "Plain Text Transmission of Username and Password in the URL",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eFor Enterprise Analytics: Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \u201dSICK Operating Guidelines\u201d and \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices.\u003c/p\u003e"
}
],
"value": "For Enterprise Analytics: Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \u201dSICK Operating Guidelines\u201d and \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices."
}
],
"x_generator": {
"engine": "csaf2cve 0.2.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2025-58584",
"datePublished": "2025-10-06T07:01:04.945Z",
"dateReserved": "2025-09-03T08:58:14.356Z",
"dateUpdated": "2026-05-13T11:55:11.969Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-57800 (GCVE-0-2025-57800)
Vulnerability from cvelistv5 – Published: 2025-08-22 17:02 – Updated: 2025-08-22 17:25
VLAI
EPSS
VEX
Title
Audiobookshelf vulnerable to OIDC token exfiltration and account takeover
Summary
Audiobookshelf is an open-source self-hosted audiobook server. In versions 2.6.0 through 2.26.3, the application does not properly restrict redirect callback URLs during OIDC authentication. An attacker can craft a login link that causes Audiobookshelf to store an arbitrary callback in a cookie, which is later used to redirect the user after authentication. The server then issues a 302 redirect to the attacker-controlled URL, appending sensitive OIDC tokens as query parameters. This allows an attacker to obtain the victim's tokens and perform full account takeover, including creating persistent admin users if the victim is an administrator. Tokens are further leaked via browser history, Referer headers, and server logs. This vulnerability impacts all Audiobookshelf deployments using OIDC; no IdP misconfiguration is required. The issue is fixed in version 2.28.0. No known workarounds exist.
Severity
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-22 17:25 UTC
CWE
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://github.com/advplyr/audiobookshelf/securit… | x_refsource_CONFIRM |
| https://github.com/advplyr/audiobookshelf/commit/… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| advplyr | audiobookshelf |
Affected:
>= 2.6.0, < 2.28.0
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-57800",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-22T17:25:36.806957Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T17:25:46.579Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "audiobookshelf",
"vendor": "advplyr",
"versions": [
{
"status": "affected",
"version": "\u003e= 2.6.0, \u003c 2.28.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Audiobookshelf is an open-source self-hosted audiobook server. In versions 2.6.0 through 2.26.3, the application does not properly restrict redirect callback URLs during OIDC authentication. An attacker can craft a login link that causes Audiobookshelf to store an arbitrary callback in a cookie, which is later used to redirect the user after authentication. The server then issues a 302 redirect to the attacker-controlled URL, appending sensitive OIDC tokens as query parameters. This allows an attacker to obtain the victim\u0027s tokens and perform full account takeover, including creating persistent admin users if the victim is an administrator. Tokens are further leaked via browser history, Referer headers, and server logs. This vulnerability impacts all Audiobookshelf deployments using OIDC; no IdP misconfiguration is required. The issue is fixed in version 2.28.0. No known workarounds exist."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-523",
"description": "CWE-523: Unprotected Transport of Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-601",
"description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T17:02:04.472Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/advplyr/audiobookshelf/security/advisories/GHSA-vpc2-w73p-39px",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/advplyr/audiobookshelf/security/advisories/GHSA-vpc2-w73p-39px"
},
{
"name": "https://github.com/advplyr/audiobookshelf/commit/99a3867ce934b797e21e6ba5390d4b679e35f7cb",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/advplyr/audiobookshelf/commit/99a3867ce934b797e21e6ba5390d4b679e35f7cb"
}
],
"source": {
"advisory": "GHSA-vpc2-w73p-39px",
"discovery": "UNKNOWN"
},
"title": "Audiobookshelf vulnerable to OIDC token exfiltration and account takeover"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2025-57800",
"datePublished": "2025-08-22T17:02:04.472Z",
"dateReserved": "2025-08-20T14:30:35.009Z",
"dateUpdated": "2025-08-22T17:25:46.579Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-54542 (GCVE-0-2025-54542)
Vulnerability from cvelistv5 – Published: 2025-08-28 10:12 – Updated: 2025-08-28 13:36
VLAI
EPSS
VEX
Title
Sending Password in GET Request
Summary
QuickCMS sends password and login via GET Request. This allows a local attacker with access to the victim's browser history to obtain the necessary credentials to log in as the user.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version 6.8 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-28 13:35 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert.pl/posts/2025/08/CVE-2025-54540 | third-party-advisory |
| https://opensolution.org | product |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| OpenSolution | QuickCMS |
Affected:
6.8
(semver)
|
Date Public
2025-08-25 09:55
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54542",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-28T13:35:52.999462Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T13:36:30.203Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "QuickCMS",
"vendor": "OpenSolution",
"versions": [
{
"status": "affected",
"version": "6.8",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Karol Czubernat"
}
],
"datePublic": "2025-08-25T09:55:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "QuickCMS sends password and login via GET Request. This allows a\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003elocal\u003c/span\u003e attacker with access to the victim\u0027s browser history to obtain the necessary credentials to log in as the user.\u003cbr\u003e\u003cbr\u003eThe vendor was notified early about this vulnerability, but didn\u0027t respond with the details of vulnerability or vulnerable version range. Only version 6.8 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "QuickCMS sends password and login via GET Request. This allows a\u00a0local attacker with access to the victim\u0027s browser history to obtain the necessary credentials to log in as the user.\n\nThe vendor was notified early about this vulnerability, but didn\u0027t respond with the details of vulnerability or vulnerable version range. Only version 6.8 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERALin"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-28T10:13:32.629Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2025/08/CVE-2025-54540"
},
{
"tags": [
"product"
],
"url": "https://opensolution.org"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Sending Password in GET Request",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2025-54542",
"datePublished": "2025-08-28T10:12:38.118Z",
"dateReserved": "2025-07-24T13:28:55.489Z",
"dateUpdated": "2025-08-28T13:36:30.203Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-52901 (GCVE-0-2025-52901)
Vulnerability from cvelistv5 – Published: 2025-06-30 19:56 – Updated: 2025-08-04 17:22
VLAI
EPSS
VEX
Title
File Browser allows sensitive data to be transferred in URL
Summary
File Browser provides a file managing interface within a specified directory and it can be used to upload, delete, preview, rename and edit files. Prior to version 2.33.9, access tokens are used as GET parameters. The JSON Web Token (JWT) which is used as a session identifier will get leaked to anyone having access to the URLs accessed by the user. This will give an attacker full access to a user's account and, in consequence, to all sensitive files the user has access to. This issue has been patched in version 2.33.9.
Severity
4.5 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-30 20:25 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://github.com/filebrowser/filebrowser/securi… | x_refsource_CONFIRM |
| https://github.com/filebrowser/filebrowser/commit… | x_refsource_MISC |
| https://github.com/filebrowser/filebrowser/releas… | x_refsource_MISC |
| https://github.com/sbaresearch/advisories/tree/pu… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| filebrowser | filebrowser |
Affected:
< 2.33.9
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-52901",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-30T20:25:07.286948Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T20:25:15.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "filebrowser",
"vendor": "filebrowser",
"versions": [
{
"status": "affected",
"version": "\u003c 2.33.9"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "File Browser provides a file managing interface within a specified directory and it can be used to upload, delete, preview, rename and edit files. Prior to version 2.33.9, access tokens are used as GET parameters. The JSON Web Token (JWT) which is used as a session identifier will get leaked to anyone having access to the URLs accessed by the user. This will give an attacker full access to a user\u0027s account and, in consequence, to all sensitive files the user has access to. This issue has been patched in version 2.33.9."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-04T17:22:39.525Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/filebrowser/filebrowser/security/advisories/GHSA-rmwh-g367-mj4x",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/filebrowser/filebrowser/security/advisories/GHSA-rmwh-g367-mj4x"
},
{
"name": "https://github.com/filebrowser/filebrowser/commit/d5b39a14fd3fc0d1c364116b41289484df7c27b2",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/filebrowser/filebrowser/commit/d5b39a14fd3fc0d1c364116b41289484df7c27b2"
},
{
"name": "https://github.com/filebrowser/filebrowser/releases/tag/v2.33.9",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/filebrowser/filebrowser/releases/tag/v2.33.9"
},
{
"name": "https://github.com/sbaresearch/advisories/tree/public/2025/SBA-ADV-20250327-03_Filebrowser_Sensitive_Data_Transferred_In_URL",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/sbaresearch/advisories/tree/public/2025/SBA-ADV-20250327-03_Filebrowser_Sensitive_Data_Transferred_In_URL"
}
],
"source": {
"advisory": "GHSA-rmwh-g367-mj4x",
"discovery": "UNKNOWN"
},
"title": "File Browser allows sensitive data to be transferred in URL"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2025-52901",
"datePublished": "2025-06-30T19:56:25.114Z",
"dateReserved": "2025-06-20T17:42:25.711Z",
"dateUpdated": "2025-08-04T17:22:39.525Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-49188 (GCVE-0-2025-49188)
Vulnerability from cvelistv5 – Published: 2025-06-12 14:02 – Updated: 2025-06-17 19:04
VLAI
EPSS
VEX
Title
Sensitive Data in URL
Summary
The application sends user credentials as URL parameters instead of POST bodies, making it vulnerable to information gathering.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-12 14:14 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://sick.com/psirt | x_SICK PSIRT Website |
| https://cdn.sick.com/media/docs/1/11/411/Special_… | x_SICK Operating Guidelines |
| https://www.cisa.gov/resources-tools/resources/ic… | x_ICS-CERT recommended practices on Industrial Security |
| https://www.first.org/cvss/calculator/3.1 | x_CVSS v3.1 Calculator |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisory |
| https://www.sick.com/.well-known/csaf/white/2025/… | vendor-advisoryx_csaf |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| SICK AG | SICK Field Analytics |
Affected:
all versions
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-49188",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-12T14:14:35.551923Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T19:04:38.200Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SICK Field Analytics",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all versions",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ccode\u003eThe application sends user credentials as URL parameters instead of POST bodies, making it vulnerable to information gathering.\u003c/code\u003e"
}
],
"value": "The application sends user credentials as URL parameters instead of POST bodies, making it vulnerable to information gathering."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-12T14:02:36.838Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"x_SICK PSIRT Website"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"x_SICK Operating Guidelines"
],
"url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
},
{
"tags": [
"x_ICS-CERT recommended practices on Industrial Security"
],
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"tags": [
"x_CVSS v3.1 Calculator"
],
"url": "https://www.first.org/cvss/calculator/3.1"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.pdf"
},
{
"tags": [
"vendor-advisory",
"x_csaf"
],
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0007.json"
}
],
"source": {
"advisory": "sca-2025-0007",
"discovery": "INTERNAL"
},
"title": "Sensitive Data in URL",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003ccode\u003ePlease make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \\\"SICK Operating Guidelines\\\" and \\\"ICS-CERT recommended practices on Industrial Security\\\" could help to implement the general security practices.\u003c/code\u003e"
}
],
"value": "Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The collected resources \\\"SICK Operating Guidelines\\\" and \\\"ICS-CERT recommended practices on Industrial Security\\\" could help to implement the general security practices."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2025-49188",
"datePublished": "2025-06-12T14:02:36.838Z",
"dateReserved": "2025-06-03T05:55:52.772Z",
"dateUpdated": "2025-06-17T19:04:38.200Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41772 (GCVE-0-2025-41772)
Vulnerability from cvelistv5 – Published: 2026-03-09 08:18 – Updated: 2026-03-09 18:18
VLAI
EPSS
VEX
Title
wwwupdate.cgi Session token in URL
Summary
An unauthenticated remote attacker can obtain valid session tokens because they are exposed in plaintext within the URL parameters of the wwwupdate.cgi endpoint in UBR.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-03-09 18:17 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41772",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-09T18:17:43.406586Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T18:18:41.648Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UBR-01 Mk II",
"vendor": "MBS",
"versions": [
{
"lessThan": "6.0.1.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UBR-02",
"vendor": "MBS",
"versions": [
{
"lessThan": "6.0.1.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UBR-LON",
"vendor": "MBS",
"versions": [
{
"lessThan": "6.0.1.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Adrien Rey from Cyber Defense Campus Zurich"
},
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Daniel Hulliger from Armasuisse"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can obtain valid session tokens because they are exposed in plaintext within the URL parameters of the wwwupdate.cgi endpoint in UBR.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can obtain valid session tokens because they are exposed in plaintext within the URL parameters of the wwwupdate.cgi endpoint in UBR."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-09T08:18:49.918Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.mbs-solutions.de/mbs-2025-0001"
}
],
"source": {
"defect": [
"CERT@VDE#641895"
],
"discovery": "UNKNOWN"
},
"title": "wwwupdate.cgi Session token in URL",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41772",
"datePublished": "2026-03-09T08:18:49.918Z",
"dateReserved": "2025-04-16T11:18:45.761Z",
"dateUpdated": "2026-03-09T18:18:41.648Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40742 (GCVE-0-2025-40742)
Vulnerability from cvelistv5 – Published: 2025-07-08 10:35 – Updated: 2026-05-12 08:20
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-08 20:32 UTC
CWE
- CWE-598 - Use of GET Request Method With Sensitive Query Strings
Assigner
References
1 reference
Impacted products
64 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIPROTEC 5 6MD84 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 6MD86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MD89 (CP300) V9.6x |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 6MU85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7KE85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SA82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA84 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SA86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SA87 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SD82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD84 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SD86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SD87 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ81 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SJ86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SK82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SK85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SL82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SL86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SL87 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7SS85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7ST85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7ST86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SX82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SX85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7SY82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UM85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP100) |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT82 (CP150) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT86 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7UT87 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VE85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP200) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SIPROTEC 5 7VK87 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 7VU85 (CP300) |
Affected:
0 , < V11.0
(custom)
|
|
| Siemens | SIPROTEC 5 Compact 7SX800 (CP050) |
Affected:
0 , < V11.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40742",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T20:32:17.016526Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T20:32:25.319Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA84 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD84 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP100)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP200)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V11.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003c V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions \u003c V11.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598: Use of GET Request Method With Sensitive Query Strings",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:20:43.164Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-904646.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40742",
"datePublished": "2025-07-08T10:35:02.095Z",
"dateReserved": "2025-04-16T08:39:30.029Z",
"dateUpdated": "2026-05-12T08:20:43.164Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
Implementation
When sending sensitive information, only include it in the request body or request headers instead of the query string. This may require avoiding use of GET requests.
No CAPEC attack patterns related to this CWE.